• Endress+Hauser Proline Promass Q 300 Coriolis flowmeter,MY SHOP,Endress+Hauser Proline Promass Q 300 Coriolis flowmeter
  • Endress+Hauser Proline Promass Q 300 Coriolis flowmeter,MY SHOP,Endress+Hauser Proline Promass Q 300 Coriolis flowmeter

Endress+Hauser Proline Promass Q 300 Coriolis flowmeter

Download
View all downloads
  • Endress+Hauser Proline Promass Q 300 Coriolis flowmeter,MY SHOP,Endress+Hauser Proline Promass Q 300 Coriolis flowmeter

Description

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.25 %
    Density (liquid): +/-0.2 kg/m³ (standard), +/-0.1 kg/m³ (option)

  • Measuring range

    0 to 2 400 000 kg/h (0 to 88183 lb/min)

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)