Optiwave & Optiflex Selection Center

Optiwave & Optiflex Selection Center

Choose the right instrument from the KROHNE radar family on our krohne optiwave 5200 product page: FMCW non-contact measurement of liquids, pastes and corrosive media up to 98.4 ft (30 m), SIL2-compliant to IEC 61508, with PP or PTFE wave horn antennas and backwards compatibility with all BM 70x flange systems. If you are specifying a krohne radar level meter for a chemical, pharmaceutical, water treatment or power project, the application triage, model ladder and spec table below show what decides the order — then send your process data for a model recommendation and quote.

Up to 30 m98.4 ft non-contact range
SIL2Compliant to IEC 61508
PP or PTFEWave horn antennas
OPTIWAVE 5200 C/F Non-Contact Radar Level Meter,MY SHOP,OPTIWAVE 5200 C/F Non-Contact Radar Level Meter
Model ladder

Which KROHNE radar family covers your tank?

Liquids and pastes, solid applications and the wider KROHNE line are not interchangeable. These cards set out the headline facts of each family before you compare the detail.

KROHNE OPTIWAVE 5200C/F non-contact radar level meter
Non-contact • Liquids & pastes

OPTIWAVE 5200C/F

  • TechnologyFMCW radar, non-contact
  • RangeUp to 98.4 ft (30 m)
  • AntennaPP or PTFE wave horn
  • SafetySIL2 per IEC 61508
  • MediaLiquids, pastes, corrosive products
Open the 5200C/F product page →
OPTIWAVE 5200 C/F Non-Contact Radar Level Meter,MY SHOP,OPTIWAVE 5200 C/F Non-Contact Radar Level Meter
Non-contact • Solids

OPTIWAVE 6300

  • TechnologyFMCW radar, non-contact
  • ApplicationSolid applications, per its listing
  • RangeSee the 6300 product listing
  • AntennaSee the 6300 product listing
  • SafetySee the 6300 product listing
Open the 6300 product page

OPTIWAVE 5200 C/F Non-Contact Radar Level Meter,MY SHOP,OPTIWAVE 5200 C/F Non-Contact Radar Level Meter
OPTIFLEX 1300C and further Krohne models

  • Covered hereThe 5200C/F and 6300 radar lines
  • Also listedOPTIFLEX 1300C and the OPTIFLUX flow lines
  • DataModel-level data on request
  • Why it mattersOne supplier can cover level and flow tags
See the full listing →
Head-to-head

Specification comparison: 5200C/F against the 6300

Both are non-contact FMCW instruments, but they are aimed at different contents. Everything below is the published position of each listing — nothing is inferred.

Specification OPTIWAVE 5200C/FLiquids, pastes, corrosive media OPTIWAVE 6300Solid applications
Measurement technology FMCW radar, non-contact FMCW radar level transmitter, non-contact
Max measuring range Up to 98.4 ft (30 m) See the 6300 listing
Media suitability Liquids and pastes, including corrosive products and aggressive paste materials Solid applications
Antenna / process material PP (polypropylene) or PTFE (polytetrafluoroethylene) wave horn antennas See the 6300 listing
Measured variables Distance, level and volume Level, per the 6300 listing
Safety rating SIL2-compliant according to IEC 61508 See the 6300 listing
Housing and mounting Horizontal or vertical housing position, 360° rotation, bayonet cover, quick coupling system for removal under process conditions See the 6300 listing
Local interface Optional local display with integrated 4-button keypad, accessible without removing the housing cover See the 6300 listing
Flange compatibility Converter backwards compatible with all BM 70x flange systems See the 6300 listing
Calibration Each device calibrated on dedicated calibration rigs before it leaves the factory See the 6300 listing

Where the table says “See the 6300 listing”, that figure is published on the OPTIWAVE 6300 product page rather than on this one. Open it, or ask an engineer for the current datasheet of either model.

Scenario to specification

From your process condition to the specs to confirm

Four common buying situations, the specifications that actually change the order, and what to do next. Confirm each line with the engineering team before you release a purchase order.

01

Corrosive chemical stored in a tank

  • Antenna material: PP or PTFE wave horn
  • Medium and concentration for material confirmation
  • Process temperature and pressure at the nozzle

Send the chemistry so the wave horn material is confirmed against your specific product.

02

Solid material in a silo

  • Solid applications sit with the OPTIWAVE 6300
  • Confirm range, antenna and safety data on that listing
  • Share silo height and filling profile

Open the 6300 page or ask for a model comparison against the 5200C/F.

03

Hygienic pharmaceutical or water service

  • Non-contact measurement: no medium contact
  • Distance, level and volume from one device
  • Optional local display with a 4-button keypad

Request a configuration matched to your cleaning and documentation needs.

04

Retrofit on an existing BM 70x flange

  • Backwards compatible with all BM 70x flange systems
  • Housing can sit horizontally or vertically, 360° rotation
  • State the installed flange standard and rating

Read the flange-swap explainer and bring your flange details to the enquiry form.

What decides the order

Three specifications that change the purchase

Range, antenna material and flange continuity are where most level-meter projects stall. Each one is explained below, and each one ends in the same place: the data you send with your enquiry.

01 — RANGE

What a 30 m (98.4 ft) range really gives you

The OPTIWAVE 5200C/F is specified for a measuring range of up to 98.4 ft (30 m). Treat that as the ceiling, not the guaranteed working span: foam, condensation, nozzle height and vessel shape — a tall narrow tank behaves differently from a wide flat one — all reduce the usable range. Send a simple sketch with tank height, nozzle length and the highest and lowest levels you need, and range can be matched to geometry instead of a headline figure.

Send your tank sketch with your enquiry →

02 — ANTENNA MATERIAL

PP or PTFE for aggressive media

Both PP (polypropylene) and PTFE (polytetrafluoroethylene) wave horn antennas are offered, and both are listed for measuring corrosive products. The choice is chemical rather than cosmetic: give the medium, its concentration and the process temperature so the antenna material can be confirmed against that specific chemistry. Because the measurement is non-contact, the antenna never touches the product, which keeps build-up, cleaning and contamination off the wetted-part list entirely.

Send the medium and concentration with your enquiry →

03 — FLANGE CONTINUITY

Reusing a BM 70x flange on a retrofit

The converter is backwards compatible with all BM 70x flange systems, which is what makes a like-for-like replacement practical: in most cases the existing flange stays on the nozzle and only the electronics and antenna are replaced. Check two things before you commit — the flange standard and rating currently installed, and the housing position your installation needs, since the housing can sit horizontally or vertically with 360° rotation and the bayonet cover opens without removing the housing.

Confirm your flange standard → through the enquiry form below.

Request for quote

Send these details and we return a model and a quote

The faster the process data arrives, the faster the model, antenna and flange can be pinned down. One tag or a full project list — both work.

  • Medium and concentration — what is in the vessel and how aggressive it is.
  • Process temperature and pressure — normal and maximum values at the nozzle.
  • Tank or silo height, nozzle length and position — plus the highest and lowest levels to be measured.
  • Required approvals and documentation — certificates and calibration records you need with the order.
  • SIL requirement — whether the loop is safety-related and needs the SIL2 rating to IEC 61508.
  • Existing flange standard and rating — for example an installed BM 70x flange to be reused.
  • Preferred output, display and housing position — including whether the optional local display is wanted.

Talk to an Engineer

Send these seven points and the engineering team replies with a recommended model, antenna material and a quote for your project quantity.

Send your process data Prefer to read first? Open the product page for downloads →
Pre-sales questions

Engineering FAQs before you order

The questions that come up most often between specification and purchase order.

What does the OPTIWAVE 5200C/F measure, and in which industries?

It is a non-contact FMCW radar level meter that measures distance, level and volume of liquids and pastes, including corrosive products and aggressive paste materials. The product page lists chemical, pharmaceutical, water treatment and power as application industries.

How far can the measurement reach?

The stated measuring range is up to 98.4 ft (30 m). Tank height, nozzle position and the geometry around the antenna all affect how much of that range is usable, so send a simple tank sketch with your enquiry.

Should I choose a PP or a PTFE wave horn antenna?

Both PP (polypropylene) and PTFE (polytetrafluoroethylene) wave horn antennas are offered, and both are listed for measuring corrosive products. Share the medium and its concentration so the antenna material can be confirmed against your specific chemical and process temperature.

Can I replace an installed KROHNE BM 70x with this converter?

The converter is backwards compatible with all BM 70x flange systems, so the existing flange can normally stay on the nozzle while the electronics and antenna are replaced. Confirm your flange standard and rating with the team before ordering.

Is it suitable for safety-related systems?

The unit is SIL2-compliant according to IEC 61508. Each device is also calibrated on dedicated calibration rigs before it leaves the factory, and calibration documentation can be requested with your order.

How do I get a model recommendation and a quote?

Send the medium, concentration, process temperature and pressure, tank or silo height and nozzle, required approvals, SIL requirement and existing flange standard through the contact page. The engineering team replies with a recommended model and a quote.

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

What Does a 30 m Measuring Range Mean for Radar Level Transmitters?

A 30 m measuring range describes how far a radar level transmitter can measure when the liquid surface reflects a strong echo, so the practical distance depends on the material in

Read article

Replacing KROHNE BM70x Radar Level Meters Without Flange Changes

A KROHNE BM70x radar level meter becomes a scheduled replacement candidate when continued operation turns into a spare-part, calibration, or maintenance risk, and a flange-compatib

Read article

PP and PTFE Radar Level Meter Antennas for Corrosive Chemical Tanks

Selecting a radar level meter for a corrosive chemical tank starts with the wave horn because the antenna remains exposed to the process atmosphere even when the transmitter electr

Read article

Frequently Asked Questions

what information is shown for this product?

review the product details, images, and specifications presented on the official product page.

where can i check the intended application?

use the application and use-case information published on the official product page.

which specifications should i confirm before ordering?

confirm the specifications and options listed for the exact product variant before placing an order.

where can i check available options?

check the official product page or ask the supplier about options shown for the selected product.

how can i request product information?

use the official contact or inquiry path provided on the site.

what should i include in an inquiry?