• Endress+Hauser Proline Promag W 800 electromagnetic flowmeter,MY SHOP,Endress+Hauser Proline Promag W 800 electromagnetic flowmeter
  • Endress+Hauser Proline Promag W 800 electromagnetic flowmeter,MY SHOP,Endress+Hauser Proline Promag W 800 electromagnetic flowmeter

Endress+Hauser Proline Promag W 800 electromagnetic flowmeter

Download
View all downloads
  • Endress+Hauser Proline Promag W 800 electromagnetic flowmeter,MY SHOP,Endress+Hauser Proline Promag W 800 electromagnetic flowmeter

Description

  • Max. measurement error

    Volume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)

  • Measuring range

    9 dm³/min to 22500 m³/h (2.5 to 100000 gal/min)

  • Medium temperature range

    Liner material hard rubber: 0 to +70 °C (+32 to +158 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: -20 to 70°C (–4 to +158 °F)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Wetted materials

    Liner: polyurethane; PTFE; hard rubber
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)